HE Series
CLASS I DIVISION 2 EMERGENCY LIGHTING
Page 1 of 2
Job Information Type:
Job Name:
Cat. No.:
Notes:
Features
Illumination: Illumination
is accomplished with lamp
heads mounted on the top of
the unit. The Class I, Div. 2
rated “H” Series lamp head
is available in a variety of
wattages, and is constructed of
gray polycarbonate to match
the housing.
Housing: Constructed of
impact-resistant, fiberglass-
reinforced polyester. Housing
color is gray and includes
stainless steel hardware. The
HE Series is UL listed for
Class I, Division 2, Groups
A, B, C & D; Class I, Zone
2, Groups IIA, IIB (+ H
2
) &
IIC; and Class II, Division 2,
Groups F & G. View-through
window allows easy monitoring
of the optional voltmeter and
ammeter. Available with Class
I, Div. 2 rated polycarbonate
sealed beam Par 36 tungsten or
halogen lamp heads.
Operating Temperature
Range: Standard location
65°F (19°C) to 85°F (30°C)
Electrical Specifications:
Lead Calcium
6 VDC 25 & 50 W:
0.18 A (120), 0.08 A (277)
12 VDC 25, 50, 100 & 125 W:
0.40 A (120), 0.18 A (277)
NiCad
6 & 12 VDC 25 W:
0.088 A (120), 0.042 A (277)
6 VDC 50 & 75 W, 12 VDC
50 W:
0.19 A (120), 0.084 A (277)
12 VDC 75 & 100 W:
0.29 A (120), 0.14 A (277)
12 VDC 125 & 150 W:
0.39 A (120), 0.18 A (277)
Diagnostic Electronics
(standard): 120/277 VAC
dual voltage input with surge
protection is standard on all
models. Charging system is
microprocessor driven with
software embedded diagnostic
routine and precision
temperature compensation.
Surge protection, brownout,
AC lockout, and low voltage
disconnect features are
standard.
Self-Testing Diagnostics
(optional): The diagnostic/
charging platform with self-
testing mode automatically
runs a one-minute self-test
every 30 days and a 30-minute
test on the sixth and twelfth
month. A one-minute or
90-minute test may be initiated
via the push to test switch on
the unit or by activating the
appropriate test command on
the optional IR test device.
Code Compliance
UL 924 and 844 listed. NFPA
101, NEC, BOCA, OSHA and
IBC illumination standards.
Temperature Rating (T-Rating)
160° (T3C). Class I, Zone 2
T-Rating 200° (T3).
Warranty
Three year full electronics
warranty. One year full plus
four year prorated lead calcium
battery warranty. Five year full
plus five year prorated nickel
cadmium battery warranty.
13.2"
(33.5 cm)
15.2"
(38.6 cm)
HE125L2HH8SD2
7.1"
(18.0 cm)
21.4"
(54.4 cm)
Vue de la page 0